Understanding common building defects
THE DILAPIDATION SURVEY REPORTSource: http://www.hbp.usm.my/conservation/DilapidationSurvey.htm
Article published in "Majalah Akitek", Volume 16, Issue 1, First Quarter
2004, pg. 19-21
By Associate Professor Dr. A Ghafar Ahmad School of Housing,
Building and Planning Universiti Sains Malaysia, Penang
The practice of securing information on heritage buildings has been
considered fundamental towards understanding the existing building
conditions and defects. Such detailed and systematic collection and
documentation of vital building information is commonly known as the
dilapidation survey. In Malaysia and elsewhere, the dilapidation surveys
are gaining momentum and are often required by the building owners or
clients. Dilapidation surveys are usually prepared in anticipation of the
work required to rectify any identified building defect; hence, they are
best conducted as part and parcel of the documentation for these works. A
poor understanding regarding the extent and nature of the building defects
would render an inappropriate approach and scope of repair work being
carried out during the conservation project - leading to disagreements and
substantial costs implications amongst building owners, clients and
contractors.
A dilapidation survey is the practice of identifying and recording
building defects through the means of photographic and digital
documentation prior to any conservation work. The survey - usually carried
out by building conservators - requires in-depth analyses of the building
defects, probable causes and the proposed methods and techniques of
building conservation. Normally, data and information obtained from the
dilapidation survey are analyzed, documented and presented in a technical
report: which is used for preparing project briefs, building
specifications and the Bill of Quantity (BQ).
As building conservation often involves various remedial works and
building repairs, a thorough identification and recording of building
defects are integral in determining the appropriate conservation methods
and techniques to be employed. Hence, dilapidation surveys involve
historians, architects, conservators, structural engineers, mechanical and
electrical, and quantity surveyors. Occasionally, the expertise of
microbiologists, chemists, archaeologists and geologists are also sought.
For instance, in the restoration of the Fort Cornwallis in Georgetown,
Penang, microbiologists were consulted on the treatment of harmful growth
and fungus stain, whilst archaeologists were engaged to conduct
archaeological works, especially in tracing the demolished old fort walls
and remnants of the structure. In the practice of building conservation,
dilapidation surveys are generally instrumental in regard of the following
aspects:
Understanding the state of the building defects
Determining the causes of the building defects
Identifying appropriate methods and techniques of building conservation
Providing reference materials to clients, consultants and project
contractors
Providing a vital resource for conducting the Historical Architectural
Building Survey (HABS)
As recording and documenting are the basic components of the dilapidation
surveys, a thorough investigation of the building conditions, defects and
their causes are necessary. The conditions and nature of the existing
building materials should be well captured in both photographic and
digital forms for purposes of documentation. Existing building materials -
whether timber, brick, stone, plaster or concrete - should be fully
examined and documented. The same goes for the condition of roof
structures, floors, doors, windows, staircases and foundation.
Balustrades, pinnacles, cornices or festoons that have been broken or
missing in the past should also be noted. The exact locations of all
building defects should be marked clearly and plotted onto floor plans,
sections and elevations. For cross-referencing purposes, windows, doors,
staircases and rooms should be coded.
Studies on heritage buildings in Malaysia have highlighted several
building defects that are commonly found:
Fungus stain and harmful growth
Fungal stains or mould occur when there is moisture content in the walls.
It flourishes in an environment of high humidity with lack of ventilation.
Harmful growth includes creeping and ivy plants that can grow either on
walls, roofs or gutters. This usually happens when dirt penetrate small
openings in the walls and mortar joints, creating suitable grounds for
seeds to grow. Roots can go deep into the existing holes causing further
cracks and water penetration.
Erosion of Mortar Joints
The main function of a mortar joint is to even out the irregularities of
individual blocks either stones or bricks. Causes of mortar joint erosion
include salt crystallization, scouring action of winds, the disintegrating
effects of wall-growing plant, and water penetration resulting in
dampness. Decayed mortar can be forcibly removed with a mechanical disc or
manually raked out using a knife or spike.
Peeling Paint
Peeling paint usually occurs on building facades, mainly on plastered
walls, columns and other areas that are exposed to excessive rain and
dampness. Some buildings located near the sea may face a greater risk. The
amount of constant wind, rain and sun received can easily turn the
surfaces of the paint to become chalky and wrinkled or blistered. As is
the case in many heritage buildings, several layers of paints have been
applied onto the plastered walls over the decades. Apart from lime wash,
other types of paints used include emulsion, oil-based, tar, bituminous
and oil-bound water paint. Different types of paints require different
methods of removal depending on their nature.
Defective Plastered Renderings
Defective plastered rendering occurs mostly on the external walls, columns
and ceiling. In a humid tropical climate like Malaysia, defective
renderings are normally caused by biological attacks arising from
penetrating rain, evaporation, condensation, air pollution, dehydration
and thermal stress. Other causes may be the mould or harmful growth,
insects, animals and traffic vibration. Prior to being decomposed and
broken apart, renderings may crack due to either shrinkage or movement in
the substrate.
Cracking of Walls and Leaning Walls
External walls may be harmful to a building if they are structurally
unsound. Vertical or diagonal cracks in the wall are common symptoms of
structural instability. Such defects should be investigated promptly and
the causes diagnosed: be it the foundations, weak materials and joints; or
any shrinkage or thermal movements such as those of timber window frames.
Diagonal cracks, usually widest at the foundations and may terminate at
the corner of a building, often occur when shallow foundations are laid on
shrinkable sub-soil which is drier than normal or when there is a physical
uplifting action of a large tree’s main roots close to the walls. Common
causes of leaning walls include a spreading roof which forces the weight
of a roof down towards the walls, sagging due to soil movement, weak
foundations due to the presence of dampness, shrinkable clay soil or
decayed building materials; and disturbance of nearby mature trees with
roots expanding to the local settlement.
Defective Rainwater Goods
Problems associated with the defective rainwater goods include sagging or
missing eaves, gutters, corroded or broken downpipes, and leaking
rainwater heads. Other problems include undersized gutters or downpipes
which cause an overflow of water during heavy rain, and improper disposal
of water at ground level. Due to inadequate painting, iron rainwater goods
can rust and fracture. Lack of proper wall fixings, particularly by
projecting lead ears or lugs can cause instability to the downpipes. If
routine building inspections and maintenance have been neglected,
rainwater goods can be easily exposed to all sorts of defects.
Decayed Floorboards
Widely used in many heritage buildings including churches, schools,
residences and railway stations, some timber floorboards have been
subjected to surface abuses and subsequently deteriorated: leading to
structural and public safety problems. The main causes are pest attacks,
careless lifting of weakened boards by occupants, electricians or
plumbers; lack of natural preservatives ; and corroded nails.
Insect or Termite Attacks
Timber can deteriorate easily if left exposed to water penetration, high
moisture content and loading beyond its capacity. Insect or termite
attacks pose a threat to damp and digestible timber found in wall plates,
the feet of rafters, bearing ends of beams and trusses, as well as in
timbers which are placed against or built into damp walling. It is unwise
to ignore timber that is lined with insect or termite holes because they
may in time soften the timber and form further cracks. Affected timber can
be treated by pressure-spraying with insecticide or fumigant insecticidal
processes.
Roof Defects
As roof often acts as a weather shield, it is important to treat aging
roof tiles. In Malaysia, clay roof tiles have been widely used in the
heritage buildings. Common defects of roof tiles include corrosion of
nails that fix the tiles to battens and rafters, the decay of battens, and
the cracking of tiles caused by harmful growth. Harmful growth poses a
danger to the tiles because it may lift tiles and create leaks. Another
aspect to be considered is the mortar applied for ridge tiles which tends
to decay or flake off over the years.
Dampness Penetration Through Walls
Dampness penetration through walls can be a serious matter, particularly
to buildings located near water sources. Not only does it deteriorate
building structures but also damages to furnishings. The main cause of
dampness is water entering a building through different routes. Water
penetration occurs commonly through walls exposed to prevailing wet wind
or rain. With the existence of gravity, water may penetrate through
capillaries or cracks between mortar joints, and bricks or blocks before
building up trap moisture behind hard renders. Water may also drive
further up the wall to emerge at a higher level. Dampness also occurs in
walls due to other factors such as leaking gutters or downpipes, defective
drains, burst plumbing and condensation due to inadequate ventilation.
Dampness may also enter a building from the ground through cracks or
mortar joints in the foundation walls.
Unstable Foundations
Foundations are a critical in distributing loads from roofs, walls and
floors onto the earth below. They are structurally important to the
permanence of a building and should this be lacking, it is pointless
investing on superficial restoration work. Most of the common problems
associated with the foundations depend on the geology of the ground upon
which a building stands, structural failures as well as presence and
height of a water table. Additionally, inherent failures may also happen
in a building in which has to cope and carry any unsettled problem of the
foundations. Problems of the foundations may lead to an unstable building
structure, which is unsafe to users and occupants. Unstable foundations
may occur because of several reasons including shrinking clay soil,
penetration of dampness and water that may decay walls and foundations;
presence of large trees near the building; and the undertaking of
excavations nearby. They may also occur due to traffic vibrations,
deteriorating of building materials and the increased loads, particularly
with a change in building function.
Poor Installation of Air-conditioning Units
Most heritage buildings were built without air-conditioning systems. Where
people have to contend with warm temperatures, the need to install
air-conditioning systems to meet modern building requirements seems
necessary. Subject to the building function, structures and the effects on
building fabric, one should consider several factors before installing
air-conditioning units in heritage buildings. The cooler and drier air
produced by the air-conditioning systems may cause shrinkage of building
materials. There may also be a possibility of condensation either on the
surfaces or within the structure of the fabric, eventually allowing the
build-up of mould. Moreover, it may be difficult installing the air
conditioners as evidenced by how units were haphazardly placed on windows
or the front façade of some heritage buildings. Such poor practices have
gravely affected the appearance of these heritage buildings.
After diagnosing all building conditions, defects and causes, they should
be presented with relevant graphics in the dilapidation survey report. The
use of information technology may well assist in the preparation of a
good-quality report. As a rule of thumb, a dilapidation survey report
should contain the following information:
· Cultural attributes and historical background of heritage buildings
· Architectural details and significance of heritage buildings
· Detailed explanation of building conditions, defects and their causes
· Proposed methods and techniques of building conservation
· Proposed scientific studies and tests to be carried out in the project
· Pictorial documentation on building conditions and defects
· Floor plans, sections and elevations indicating the locations of
building defects
It is essential to recommend in the dilapidation survey report the
proposed scientific studies and tests to be carried out during any
conservation work. Such scientific studies and laboratory tests are
important as they provide additional information that can lead to solving
related building problems or defects. Common scientific studies required
during the conservation works include microbiological studies to identify
plant species, dispersion agents, control ranking and chemical fungicides;
archaeological studies to trace hidden remnants; and the study of relative
humidity to gauge the local temperatures and air moisture levels. Some
examples of the laboratory tests required are the brick test to analyze
the compressive strength and level of porosity; the timber test to
identify timber species, grading and group strength; lime plaster to
determine the component elements through X-ray Fluorescence (XRF)
analysis; the salt test to detect the salt levels and the percentage of
total ions; and the paint test to classify paint types as well as colour
scheme analysis. All data and analyses generated from the scientific
studies and laboratory tests should be presented in separate reports.
To be effective, the practice of the dilapidation survey should involve a
multidisciplinary approach which requires in-depth knowledge in
conservation as well as other related fields in order to correctly assess
building defects, determine their causes, and propose restoration methods.
Relevant scientific studies and laboratory tests are equally important as
these results provide for a sound basis for decision-making in
conservation works. Callous incidences of improper diagnoses of building
conditions, and the resultant ineffective remedial measures may pose
unnecessary threats to the heritage building structures and raise concerns
over public safety. It is imperative, therefore, to invest some resources
in conducting the dilapidation survey prior to any conservation project.
The dilapidation survey report, once completed, serves as an indispensable
archival resource for future references and cyclical building maintenance
programmes. |